This is a premium cable for all types of indoor installation. Due to the full copper inner conductor, the signal loss in the cable is very low and thereby less amplification is required in your installation.
For outdoor installations, we highly recommend the coax cables with PE jacket, as this material is simply more resistant to weather conditions.
MAIN FEATURES:
- TRIAX KOKA 110 A+ Cable - LSZH white – Class Cca CPR EN50575 Compliant, CAI approved - 250m reel
- TRIAX flagship CAI certified, Class Cca, cable is designed for indoor applications and has been independently tested and certified as ‘limited contribution to a fire’.
- Meeting the standards of today and the network demands of tomorrow, this triple shielded class A+ coaxial cable delivers high quality TV signals with low LTE interference.
- With superior build quality, this is the right choice for demanding installations requiring crystal clear images and safety in case of fire, for example, public and high rise buildings.
- Class Cca -S1a,d1,a1 - CPR EN50575 Compliant – Suitable for indoor application
- LSZH (Low Smoke Zero Halogen) sheath with limited contribution to a fire
- CAI approved - cert. CAI 0150A
- Class A+ (EN 50117-2-4) & PE cable (EN 50117-2-5)
- Superior build quality and materials
- High performance even over long distances
- LTE protected – tinned copper braid & two layers foils protect signals
- LSZH (Low Smoke Zero Halogen) jacket is ideal where fire resistance is a requirement.
CONSTRUCTION
Inner conductor - material: Cu
Inner conductor - dimension: 1.02 ± 0.02mm
Dielectric - material: PE gas injected
Dielectric - dimension: 4.6 ± 0.05mm
Shield (First) foil 1 – material: Al/Pet/Al - bonded
Shield (First) foil 1 – overlap: 20%
Shield (Second) – braid material: Al
Shield (Second) – braid dimension: 0,12x6x16mm
Shield (Second) – braid coverage: 62%
Third shield – foil 2 – material: Al/Pet
Jacket – dimension: 6.8 ± 0.1mm
Jacket - material: UV resistance LSZH
SHIELDING
Screening attenuation @ 30-1000 MHz: ≥ 105dB
Screening attenuation @ 1000-2000 MHz: ≥ 100dB
Screening attenuation @ 2000-3000 MHz: ≥ 100dB
TRANSFER IMPEDANCE
Transfer Impedance @ 5-30 MHz: ≤ 5mΩ/m
LOSS
Attenuation (at 20°C) @ 5 MHz: 1.7dB
Attenuation (at 20°C) @ 50 MHz: 4.6dB
Attenuation (at 20°C) @ 200 MHz: 8,6dB
Attenuation (at 20°C) @ 470 MHz: 13.6dB
Attenuation (at 20°C) @ 800 MHz: -
Attenuation (at 20°C) @ 862 MHz: 18.8dB
Attenuation (at 20°C) @ 1000 MHz: 20.3dB
Attenuation (at 20°C) @ 1350 MHz: 24,5dB
Attenuation (at 20°C) @ 1600 MHz: -
Attenuation (at 20°C) @ 1750 MHz: 27.2dB
Attenuation (at 20°C) @ 2150 MHz: 30.6dB
RETURN LOSS
Structural return loss @ 5-470 MHz: >26dB
Structural return loss @ 470-862 MHz: -
Structural return loss @ 470-1000 MHz: >23dB
Structural return loss @ 862-2400 MHz: -
Structural return loss @ 1000-2000 MHz: >20dB
Structural return loss @ 1000-2400 MHz: -
Structural return loss @ 2000-3000 MHz: >20dB
ELECTRICAL
Insulation Resistance: >10000MΩ/km
Impedance: 75 ± 3Ω
Capacity: 52 ± 2pF/m
Velocity ratio: 84%
Inner DC resistance: <22.5Ω/km
Outer DC resistance: <20Ω/km
Conductor DC resistance @ 20°C: Ohm/km
Mutual capacity @ 1kHz: pF/m
OPERATIONAL
Application: Indoor
Fire Class: Cca
MECHANICAL
Tensile Strength - Outer Conductor 1 (Ø): 230N/mm2
Colour: White
Length (m): 250m
Minimum bending radius - single/repeated: 23/70mm