SK110plus 18 VAtC coaxial cable
Eca Euroclass, A+ Class shielded
Coaxial cable with both conductors made of copper (Cu/Cu) and outstanding braid coverage (55%). Triple shielded (TSH) cable, equipped with a second foil for extra shielded. An 18 VAtC cable with PVC sheath.
HIGHLIGHTS
- Copper conductors
- Class A+ shielded
- Eca Euroclass
MAIN FEATURES
- White-colour external PVC sheath
- 75 Ohm characteristic impedance
- Available in reels of different lengths
DISCOVER
Class A+ Trishield (TSH) coaxial cable
With three shielding layers (Trishield), this cables provide the highest immunity to interference thanks to its very high -shielding. Recommended in cases of high electromagnetic noise levels.
They belong in EN 50117 standard Class A+, according to their structural properties:
- For 5 MHz - 30 MHz => TI < 2.5 mΩ/m
- For 5 MHz - 1000 MHz => SA > 95 dB
- For 1000 MHz - 2000 MHz => SA > 85 dB
- For 2000 MHz - 3000 MHz => SA > 75 dB
Where the transfer impedance (TI) defines how effective the shielding is at low frequencies, while the shielding attenuation (SA) defines it in the 30 MHz-to-3000 MHz range.
Type: SK110plus
Standard: EN 50117-2-4
EuroClass: Eca
Class: A+
Inner conductor
Ø mm: 1.02
Material: CU
Res. Ohm/Km: <22
Dielectric
Ø mm: 4.6
Material: PEE
Overlapped foil: Aluminium + Polyester
Braid
Material: CuSn (98%Cu)
Dimensions (Ncx Nsx Ø): 16 x 6 x 0.10
Res. Ohm/Km: <15
Coverage (%): 55
2-nd foil: Yes
Petrol-Jelly: No
Outer sheath: Ø mm 6.7 Material PVC
Minimum bending radius (mm): 40
Screening attenuation @ 1GHz (dB): >95 (110 typ.)
Capacitance (pF/m): 50.2
Impedance (Ohm): 75
Transfer impedance (5-30MHz) (mOhm/m): ≤2.0
Velocity ratio (%): 82
Attenuations (dB/m)
Frequency (MHz)
5: 0.02
47: 0.05
90: 0.06
200: 0.09
500: 0.14
800: 0.18
1000: 0.21
1350: 0.24
1750: 0.28
2050: 0.3
2300: 0.31